Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Acta Ophthalmol ; 2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38155407

RESUMO

PURPOSE: To assess the accuracy of intraocular lens (IOL) power calculation in different age groups using various IOL calculation formulas. METHODS: Data from 421 eyes of 421 patients ≥60 years old (ages: 60-69, n = 131; 70-74, n = 105; 75-84, n = 158 and ≥85, n = 27), who underwent uneventful cataract surgery with SN60WF IOL implantation at John A. Moran Eye Center, Salt Lake City, USA, were retrospectively obtained. The SD of the prediction error (PE), median and mean absolute PEs and the percentage of eyes within ±0.25, ±0.50, ±0.75 and ±1.00 D were calculated after constant optimizations for the following formulas: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Haigis, Hoffer Q, Hoffer QST, Holladay 1, Kane, Radial Basis Function (RBF) 3.0 and SRK/T. Results were compared between the different age groups. RESULTS: Predictability rates within 0.25D were lower for the eldest age group compared with the other groups using the EVO 2.0 (33% vs. 37%-53%, p = 0.045), Kane (26% vs. 35%-50%, p = 0.034) and SRK/T (22% vs. 31%-49%, p = 0.002). Higher median absolute refractive errors for all formulas were observed in the oldest group [range: 0.39 D (Haigis, Hoffer QSR)-0.48 D (Kane)], followed by the youngest group [range: 0.30 D (RBF 3.0)-0.39 D (Holladay 1, SRK/T)] but did not reach statistical significance. No significant differences between the groups in the distribution parameter were seen. CONCLUSION: Current IOL power calculation formulas may have variable accuracy for different age groups. This should be taken into account when planning cataract surgery to improve refractive outcomes.

2.
Clin Ophthalmol ; 17: 2341-2347, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37600145

RESUMO

Purpose: To evaluate efficiency of grooving, nuclear fragment removal, and changes in pressure control in the Oertli Faros using traditional peristaltic and Speed and Precision (SPEEP) features. The SPEEP mode uses novel peristaltic technology permitting independent control of flow and vacuum. Methods: A porcine lens model was used with an enclosed chamber simulating the anterior segment. Grooving efficiency is evaluated with flow rates of 10, 30, and 50 mL/min using whole lenses. Lens cubes were emulsified at 20, 40, 60, 80, and 100% power with both SPEEP and non-SPEEP modes. Surge was evaluated with pressure gauges placed on the irrigation tubing and aspiration tubing. Pressure readings were recorded per the following: fluid and vacuum were initiated for 15 seconds, vacuum tubing was occluded for 5 seconds, tubing patency was then re-introduced for 15 seconds. Differences between sensors were recorded. Results: No significant increase in efficiency was seen with increasing flow rate from 30 to 50 mL/min using SPEEP. No significant differences were shown in lens fragment removal in SPEEP and non-SPEEP modes at any power tested. Pressure difference measurements were not significantly different with SPEEP and non-SPEEP modes. Conclusion: We showed that lower flow rates show comparable efficiency of grooving when using the SPEEP mode. The SPEEP function did not show increased efficiency in nuclear fragment removal when compared to traditional mode. Surge control was also comparable with both SPEEP and non-SPEEP modes. We suggest that the SPEEP function included in the Oertli Faros may have some advantages.

3.
J Cataract Refract Surg ; 49(10): 1056-1060, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37057705

RESUMO

PURPOSE: To determine whether there is a difference in efficiency during phacoemulsification when using the hybrid polymer tip compared with the metal balanced tip, as measured by cumulative dissipated energy (CDE) and total procedure time. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. DESIGN: Experimental study. METHODS: Phacoemulsification was performed with the Centurion Vision System and Infiniti OZil handpiece, with a 30-degree bevel metal balanced tip and hybrid polymer tip. The vacuum was set at 500 mm Hg and the aspiration flow rate at 50 mL/min. Power was changed for torsional and longitudinal ultrasound (US) at 20%, 40%, 60%, 80%, and 100%. Hardened porcine lenses were cut into 200 two mm cubes, 10 for each specified tip/power setting. They were placed into an artificial anterior chamber filled with a balanced salt solution, and phacoemulsification was performed. A second observer randomly assigned the US type and power. The same observer timed trials with a stopwatch, and CDE was recorded. RESULTS: There were no significant differences in time or CDE for any power levels or US modes when comparing the 2 tips. CONCLUSIONS: No significant difference in efficiency was observed when comparing the metal balanced tip with the hybrid polymer tip. Given the known improved safety profile and the overall equivalent efficiency of the hybrid tip, it could improve the performance of beginning and advanced surgeons in the future. Future study is needed to evaluate other setting combinations and to evaluate the hybrid tip in clinical settings.

4.
Clin Ophthalmol ; 17: 555-560, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36798796

RESUMO

Purpose: To understand the role of ophthalmic viscosurgical devices (OVDs) in corneal incision contracture (CIC). Specifically, the aim was to evaluate with the tip of the phacoemulsification needle free of OVD, how various OVDs near the tip and sleeve may transmit thermal energy to the incision site. Methods: A small chamber was filled with balanced saline solution (BSS), and a thin membrane was placed on the surface. OVD was placed atop the membrane. A temperature probe was placed in the OVD, while the handpiece pierced the membrane. The experiment was run both with and without flow and vacuum. Temperature measurements were gathered for each of the OVDs at four separate time points at 0 and 20mL/min flow. Results: As expected, there was a more pronounced temperature increase in all test groups with no fluid flow. While the temperature increase was not significantly different from BSS for any of the OVDs tested at either 0 or 20mL/min, Viscoat showed the most variable results at both flow settings. Conclusion: As long as the phaco tip is not in OVD, residual OVD near the incision is not exothermic and so not an additional risk for CIC.

5.
Neuropsychopharmacology ; 48(7): 1011-1020, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36807609

RESUMO

Psilocybin has been shown to improve symptoms of depression and anxiety when combined with psychotherapy or other clinician-guided interventions. To understand the neural basis for this pattern of clinical efficacy, experimental and conceptual approaches that are different than traditional laboratory models of anxiety and depression are needed. A potential novel mechanism is that acute psilocybin improves cognitive flexibility, which then enhances the impact of clinician-assisted interventions. Consistent with this idea, we find that acute psilocybin robustly improves cognitive flexibility in male and female rats using a task where animals switched between previously learned strategies in response to uncued changes in the environment. Psilocybin did not influence Pavlovian reversal learning, suggesting that its cognitive effects are selective to enhanced switching between previously learned behavioral strategies. The serotonin (5HT) 2 A receptor antagonist ketanserin blocked psilocybin's effect on set-shifting, while a 5HT2C-selective antagonist did not. Ketanserin alone also improved set-shifting performance, suggesting a complex relationship between psilocybin's pharmacology and its impact on flexibility. Further, the psychedelic drug 2,5-Dimethoxy-4-iodoamphetamine (DOI) impaired cognitive flexibility in the same task, suggesting that this effect of psilocybin does not generalize to all other serotonergic psychedelics. We conclude that the acute impact of psilocybin on cognitive flexibility provides a useful behavioral model to investigate its neuronal effects relevant to its positive clinical outcome.


Assuntos
Alucinógenos , Psilocibina , Masculino , Feminino , Animais , Ratos , Psilocibina/farmacologia , Psilocibina/uso terapêutico , Ketanserina/farmacologia , Alucinógenos/farmacologia , Ansiedade , Antagonistas do Receptor 5-HT2 de Serotonina , Serotonina , Cognição
6.
J Pharmacol Exp Ther ; 385(1): 62-75, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36669875

RESUMO

Novel psychoactive substances, including synthetic substituted tryptamines, represent a potential public health threat. Additionally, some substituted tryptamines are being studied under medical guidance as potential treatments of psychiatric disorders. Characterizing the basic pharmacology of substituted tryptamines will aid in understanding differences in potential for harm or therapeutic use. Using human embryonic kidney cells stably expressing 5-hydroxytryptamine (5-HT)1A, 5-HT2A, and 5-HT2C receptors (5-HT1AR, 5-HT2AR, and 5HT2CR, respectively) or the serotonin transporter (SERT), we measured affinities, potencies and efficacies of 21 substituted tryptamines. With the exception of two 4-acetoxy compounds, substituted tryptamines exhibited affinities and potencies less than one micromolar at the 5-HT2AR, the primary target for psychedelic effects. In comparison, half or more exhibited low affinities/potencies at 5-HT2CR, 5-HT1AR, and SERT. Sorting by the ratio of 5-HT2A to 5-HT2C, 5-HT1A, or SERT affinity revealed chemical determinants of selectivity. We found that although 4-substituted compounds exhibited affinities that ranged across a factor of 100, they largely exhibited high selectivity for 5-HT2ARs versus 5-HT1ARs and 5-HT2CRs. 5-substituted compounds exhibited high affinities for 5-HT1ARs, low affinities for 5-HT2CRs, and a range of affinities for 5-HT2ARs, resulting in selectivity for 5-HT2ARs versus 5-HT2CRs but not versus 5-HT1ARs. Additionally, a number of psychedelics bound to SERT, with non-ring-substituted tryptamines most consistently exhibiting binding. Interestingly, substituted tryptamines and known psychedelic standards exhibited a broad range of efficacies, which were lower as a class at 5-HT2ARs compared with 5-HT2CRs and 5-HT1ARs. Conversely, coupling efficiency/amplification ratio was highest at 5-HT2ARs in comparison with 5-HT2CRs and 5-HT1ARs. SIGNIFICANCE STATEMENT: Synthetic substituted tryptamines represent both potential public health threats and potential treatments of psychiatric disorders. The substituted tryptamines tested differed in affinities, potencies, and efficacies at 5-hydroxytryptamine (5-HT)2A, 5-HT2C, and 5HT1A receptors and the serotonin transporter (SERT). Several compounds were highly selective for and coupled very efficiently downstream of 5-HT2A versus 5-HT1A and 5-HT2C receptors, and some bound SERT. This basic pharmacology of substituted tryptamines helps us understand the pharmacologic basis of their potential for harm and as therapeutic agents.


Assuntos
Alucinógenos , Triptaminas , Humanos , Triptaminas/farmacologia , Serotonina/metabolismo , Proteínas da Membrana Plasmática de Transporte de Serotonina , Receptor 5-HT2A de Serotonina/metabolismo , Receptor 5-HT2C de Serotonina/metabolismo
7.
Clin Ophthalmol ; 17: 191-195, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36660311

RESUMO

Purpose: To determine the difference, if any, in grooving efficiency at various settings on the Whitestar Signature Pro phacoemulsification (phaco) system. Methods: Cataractous lenses were simulated by exposing porcine lenses to formalin for 2 hours. A total of 120 lenses were analyzed at various power settings on both longitudinal and transversal handpieces. Twenty trials each were performed with power set to 25%, 50%, and 75% on both handpieces. A Whitestar Phaco Handpiece System was used to provide longitudinal power, and a Whitestar Signature Ellipsis Handpiece provided transversal power. Lenses were placed within a plastic chamber and grooved by an investigator blinded to settings. A second investigator recorded times and adjusted settings. The Whitestar Signature Pro phaco system was used for grooving. Results: There was no significant difference in grooving times between the longitudinal and transverse handpieces at any power setting (P > 0.05). There was a significant decrease in grooving times when comparing the 25% power setting with the 75% power setting for the transversal handpiece (P=0.021). Conclusion: Both longitudinal and transversal handpieces on the Whitestar Signature Pro phaco system produce similar results to one another at each power setting. There is a general trend toward shorter grooving times, reflecting greater efficiency, at higher power settings. Grooving efficiency on the transversal handpiece may be more affected by changes in the power settings as compared with the longitudinal settings.

8.
bioRxiv ; 2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36712091

RESUMO

Psilocybin has been shown to improve symptoms of depression and anxiety when combined with psychotherapy or other clinician-guided interventions. To understand the neural basis for this pattern of clinical efficacy, experimental and conceptual approaches that are different than traditional laboratory models of anxiety and depression are needed. A potential novel mechanism is that acute psilocybin improves cognitive flexibility, which then enhances the impact of clinician-assisted interventions. Consistent with this idea, we find that acute psilocybin robustly improves cognitive flexibility in male and female rats using a task where animals switched between previously learned strategies in response to uncued changes in the environment. Psilocybin did not influence Pavlovian reversal learning, suggesting that its cognitive effects are selective to enhanced switching between previously learned behavioral strategies. The serotonin (5HT) 2A receptor antagonist ketanserin blocked psilocybin's effect on set-shifting, while a 5HT2C-selective antagonist did not. Ketanserin alone also improved set-shifting performance, suggesting a complex relationship between psilocybin's pharmacology and its impact on flexibility. Further, the psychedelic drug 2,5-Dimethoxy-4-iodoamphetamine (DOI) impaired cognitive flexibility in the same task, suggesting that this effect of psilocybin does not generalize to all other serotonergic psychedelics. We conclude that the acute impact of psilocybin on cognitive flexibility provides a useful behavioral model to investigate its neuronal effects relevant to its positive clinical outcome.

9.
Neurobiol Sleep Circadian Rhythms ; 14: 100087, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36712905

RESUMO

In mammals, sleep duration is highest in the early postnatal period of life and is critical for shaping neural circuits that control the development of complex behaviors. The prairie vole is a wild, highly social rodent that serves as a unique model for the study of complex, species-typical social behaviors. Previous work in our laboratory has found that early life sleep disruption (ELSD) in prairie voles during a sensitive window of postnatal development leads to long lasting changes in social and cognitive behaviors as well as structural changes in excitatory and inhibitory neural circuits in the brain. However, it is currently unknown how later sleep is impacted by ELSD, both shortly after ELSD and over the long term. Therefore, the aim of this study was to describe the effects of ELSD on later life sleep, compared to sleep in normally developing prairie voles. First, we conducted tethered electroencephalogram/electromyogram (EEG/EMG) recordings in juvenile prairie voles undergoing ELSD, compared to Control conditions. Second, we conducted 24 h of home cage tethered EEG/EMG recordings in either adolescent or adult male and female prairie voles that had previously undergone ELSD or Control conditions as juveniles. We found that, as adults, male ELSD prairie voles showed persistently lower REM sleep duration and female ELSD prairie voles showed persistently higher NREM sleep duration compared to Controls, but no other sleep parameters differed. We concluded that 1) persistent effects of ELSD on sleep into adulthood may contribute to the social and cognitive deficits observed in adult voles, and 2) sleep disruption early in life can influence later sleep patterns in adulthood.

10.
Can J Ophthalmol ; 58(6): 507-512, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35868436

RESUMO

OBJECTIVE: To study the thermal properties and response magnitude of a forced-infusion phacoemulsification machine on 4 ophthalmic viscosurgical devices (OVDs). DESIGN: Experimental study. METHODS: A phacoemulsification tip, thermocouple, and gauge were placed into an artificial anterior chamber with balanced saline solution (BSS) or approximately 0.1 mL of OVD. Once the thermocouple measured a consistent temperature, the pedal was engaged for 60 seconds; then the tip was removed. The machine was cooled for 5 minutes and flushed with BSS to return to baseline. This was repeated 10 times for each OVD. The research consisted of 2 scenarios: vacuum-blocked flow rate and low aspiration flow rate. RESULTS: All OVDs showed greater temperature changes than BSS. In the vacuum-blocked scenario, these increases were statistically significant. The medium viscosity dispersive OVD (DiscoVisc) reached temperatures exceeding 60°C. In the low-flow scenario, HEALON5 and DisCoVisc were significantly different at 5 seconds and only HEALON5 at 10 seconds. No temperature increases over BSS were greater than 1.0°C. CONCLUSIONS: The dispersive, cohesive, and viscoadaptive OVDs demonstrated higher temperature changes than BSS but did not reach the threshold for corneal incision contracture. The study team verified the need for at least a minimal flow rate before ultrasound, which is especially evident in the first 10 seconds, because a flow rate of only 20 mL/minute mitigated OVD-related thermal effects. Understanding thermal responses enables corneal incision contracture risk reduction.


Assuntos
Contratura , Facoemulsificação , Humanos , Combinação de Medicamentos , Sulfatos de Condroitina , Ácido Hialurônico
11.
J Cataract Refract Surg ; 48(12): 1440-1445, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36449674

RESUMO

PURPOSE: To compare the protection of the corneal endothelium provided by a cohesive and a dispersive ophthalmic viscosurgical device (OVD) against damage from torsional ultrasound and simulated lenticular debris during phacoemulsification. SETTING: University setting, Salt Lake City, Utah. DESIGN: Experimental study. METHODS: 15 New Zealand rabbits were included. After incision, each eye received cohesive or dispersive OVD (ProVisc or Viscoat). 10 1.0 mm beads were injected to simulate lenticular debris. The Intrepid Balanced tip (Centurion Ozil handpiece) was inserted into the anterior chamber, and 60% torsional ultrasound with 50 mL/min flow, 70 mm Hg intraocular pressure, and 600 mm Hg vacuum was applied (20 seconds). Cumulative dissipated energy (CDE) was noted. After euthanasia and enucleation, corneas were removed, stained with trypan blue/alizarin red, and photographed (5 ×400 magnification photos and 1 overview photograph from each cornea). ImageJ was used to evaluate cell damage and loss. RESULTS: CDE was 4.70 ± 0.26 and 4.64 ± 0.10 in the cohesive and dispersive OVD groups, respectively ( P = .8647). The analysis of the ×400 photographs showed that the percentage of intact cells was statistically higher in the dispersive OVD group ( P = .0002), whereas the percentages of damaged and lost cells were statistically higher in the cohesive OVD group ( P = .0002 and .0059, respectively). Overview photographs revealed the presence of residual OVD on the endothelium, especially in the dispersive group. CONCLUSIONS: In this experimental study using a rabbit model, the corneal endothelium protection provided by the dispersive OVD was superior to that provided by the cohesive OVD.


Assuntos
Extração de Catarata , Cristalino , Facoemulsificação , Coelhos , Animais , Endotélio Corneano , Córnea
12.
J Cataract Refract Surg ; 48(11): 1325-1330, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36026701

RESUMO

PURPOSE: To evaluate mechanical damage of simulated lenticular debris on corneal endothelial cells during phacoemulsification. SETTING: University setting, Salt Lake City, Utah. DESIGN: Experimental study. METHODS: 12 New Zealand rabbits underwent bilateral surgery. After incision, 10 1.0 mm beads were injected into the anterior chamber of test eyes to simulate lenticular debris. A balanced salt solution was injected into the contralateral eyes with the same injector. The Intrepid Balanced Tip of the Centurion Ozil handpiece was inserted into the anterior chamber, and 60% torsional ultrasound was applied for 20 seconds with 50 mL/min flow, 70 mm Hg intraocular pressure, and 600 mm Hg vacuum. Cumulative dissipated energy (CDE) was noted. After euthanasia and enucleation, the corneas were removed, stained with trypan blue/alizarin red, and photographed in a standardized manner (×400 photographs from 5 specific areas and 1 overview photograph from each corneal button). The ImageJ program was used to evaluate cell damage and loss in the photographs. RESULTS: CDE was 4.64 ± 0.19 for test eyes with beads and 4.66 ± 0.17 for control eyes without beads ( P = .58). The percentage of intact cells was statistically higher in the control group ( P = .0005), whereas the percentages of damaged and lost cells were statistically higher in the test group ( P = .0010 and .0005, respectively). This was observed in the analysis of the ×400 photographs and overview photographs. CONCLUSIONS: This study suggests that lenticular debris swirling around the anterior chamber may cause significant damage to the corneal endothelium, providing further insight on mechanisms of damage during phacoemulsification.


Assuntos
Cristalino , Facoemulsificação , Coelhos , Animais , Células Endoteliais , Endotélio Corneano , Câmara Anterior
13.
Sensors (Basel) ; 22(14)2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35891052

RESUMO

Sleep disturbances are common in older adults and may contribute to disease progression in certain populations (e.g., Alzheimer's disease). Light therapy is a simple and cost-effective intervention to improve sleep. Primary barriers to light therapy are: (1) poor acceptability of the use of devices, and (2) inflexibility of current devices to deliver beyond a fixed light spectrum and throughout the entirety of the day. However, dynamic, tunable lighting integrated into the native home lighting system can potentially overcome these limitations. Herein, we describe our protocol to implement a whole-home tunable lighting system installed throughout the homes of healthy older adults already enrolled in an existing study with embedded home assessment platforms (Oregon Center for Aging & Technology-ORCATECH). Within ORCATECH, continuous data on room location, activity, sleep, and general health parameters are collected at a minute-to-minute resolution over years of participation. This single-arm longitudinal protocol collected participants' light usage in addition to ORCATECH outcome measures over a several month period before and after light installation. The protocol was implemented with four subjects living in three ORCATECH homes. Technical/usability challenges and feasibility/acceptability outcomes were explored. The successful implementation of our protocol supports the feasibility of implementing and integrating tunable whole-home lighting systems into an automated home-based assessment platform for continuous data collection of outcome variables, including long-term sleep measures. Challenges and iterative approaches are discussed. This protocol will inform the implementation of future clinical intervention trials using light therapy in patients at risk for developing Alzheimer's disease and related conditions.


Assuntos
Doença de Alzheimer , Transtornos do Sono-Vigília , Idoso , Coleta de Dados , Estudos de Viabilidade , Humanos , Iluminação
14.
Clin Ophthalmol ; 16: 1731-1737, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35673346

RESUMO

Purpose: To determine the actual vacuum pressure generated by the Oertli CataRhex 3® (Oertli), using an external measuring system. Methods: The effective vacuum pressure created by the Oertli was measured with a pressure device that was continuous with the vacuum tubing system while closed to the external environment. Measurements were taken with the machine set to 300 and 500 mmHg at flow rates of 20, 35, and 50 mL/min and at bottle heights of 60, 80, and 100 cm. Pressures were recorded after the foot pedal was depressed to vacuum setting (second position), and the pressure was allowed to stabilize. Subsequently, it was compared to the pressure value displayed by the machine. Results: Externally measured vacuum pressure was on average 13.02% greater (39.05 mmHg) than displayed vacuum pressure at 300 mmHg (P < 0.005) and 8.60% greater (42.98 mmHg) than displayed vacuum at 500 mmHg (P < 0.005). The average difference between displayed and measured pressure increased with increasing bottle heights. Conclusion: On average, the vacuum pressure generated in the Oertli was found to be significantly higher than the machine's reading when the machine was set at 300 mmHg and 500 mmHg. Adjusting vacuum had variable effects on the measured versus displayed pressure readings.

15.
Clin Ophthalmol ; 16: 1091-1097, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35422610

RESUMO

Purpose: To evaluate the effect of each of the tip sizes available for the Oertli CataRhex3® phacoemulsification machine on efficiency. Methods: Porcine lenses were fixed in formalin for 2 hours, then cut into 3.0 mm cubes. We studied three Oertli tips, all of which had a 30-degree bevel: easyTip 2.2 mm (20G), easyTip 2.8 mm (19G), and CO-MICS (21G). For the 19G and 20G tips, vacuum was set at 600 mmHg, irrigation rate at 50 mL/min, continuous power 70%, and bottle height 85 cm. For the 21G tip, vacuum was set at 450 mmHg; irrigation and power settings were identical to those used for the easyTip tips. We measured time to removal and chatter events to determine efficiency. Results: Results from 20 trials for each tip showed that the larger the gauge size, the more quickly lens fragments were removed. Chatter events demonstrated an increasing trend with smaller tip gauge. The 19G tip used an average time to fragment removal of 2.8 seconds; the 20G, 3.2 seconds; and the 21G, 4.6 seconds. Increasing tip diameter from 21G to 20G decreased emulsification time by 33% (P = 0.02). Increasing the diameter from 21G to 19G further decreased time to emulsification by 42% (P = 0.003). The 21G tip had a mean 1.4 events/cube; 20G, 0.35 events; and 19G, 0.1 events. Differences in mean chatter events for each tip were each statistically significant. Conclusion: These data suggest that when evaluated by chatter events and emulsification time, the 2.8 mm (19G) easyTip proves to have greatest efficiency.

17.
J Cataract Refract Surg ; 48(3): 349-354, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34224479

RESUMO

PURPOSE: To compare corneal endothelial damage from longitudinal and torsional ultrasound during phacoemulsification. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN: Experimental study. METHODS: 9 New Zealand white rabbits underwent bilateral surgery. After incision, the Intrepid Balanced Tip of the Centurion Ozil handpiece was inserted into the anterior chamber, and the following settings were used: 50 mL/min flow, 70 mm Hg intraocular pressure, 600 mm Hg vacuum, and 60% longitudinal (1 eye) or torsional (contralateral eye) ultrasound for 30 seconds. Cumulative dissipated energy (CDE) was noted. After euthanasia and enucleation, the corneas were removed, stained with trypan blue/alizarin red, and photographed (400× photographs from 5 specific areas and 1 overview photograph from each corneal button). The ImageJ program was used to evaluate cell damage and loss in the photographs obtained from each cornea. RESULTS: Cavitation bubbles around the phacoemulsification tip were generally observed in the longitudinal group. CDE was 17.4 ± 0.58 and 6.93 ± 0.15 in the longitudinal and torsional groups, respectively (P = .003). The percentage of intact cells was statistically higher in the torsional group (94.22% ± 5.99% vs 56.85% ± 22.29%), and the percentage of lost cells was statistically higher in the longitudinal group (42.10% ± 22.02% vs 4.97% ± 6.23%) (P = .003). This was observed in the analysis of the 400× photographs and the overview photographs. CONCLUSIONS: This study suggests that torsional ultrasound was associated with significantly less corneal endothelial cell damage than classical longitudinal tip motion, providing further insight on mechanisms of corneal endothelial damage during phacoemulsification.


Assuntos
Extração de Catarata , Facoemulsificação , Animais , Córnea/cirurgia , Perda de Células Endoteliais da Córnea/diagnóstico , Perda de Células Endoteliais da Córnea/cirurgia , Células Endoteliais , Coelhos
18.
J Cataract Refract Surg ; 48(4): 481-486, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34371510

RESUMO

PURPOSE: To quantify the damage to the corneal endothelium from the flow of a balanced salt solution during phacoemulsification. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. DESIGN: Experimental study. METHODS: 12 New Zealand white rabbits received bilateral surgery. 6 eyes served as controls with no irrigation (incision only). In 18 eyes, the Intrepid Balanced tip of the Centurion Ozil (Alcon Laboratories, Inc.) handpiece was inserted into the anterior chamber for continuous irrigation at 50 mL/min with either 250 or 500 mL of balanced salt solution. After killing humanely and enucleation, the corneas were removed, stained with trypan blue-alizarin red, and photographed in a standardized manner (×400 photographs from 5 specific areas and 1 overview photograph from each corneal button). The ImageJ program was used to evaluate cell damage and loss in the photographs obtained from each cornea. RESULTS: Analysis of the ×400 photographs showed no statistically significant differences between control, 250 mL, and 500 mL groups in the percentage of intact, damaged, or lost cells (P = .896, .851, and .972 respectively). For the overview photographs, the differences in areas of intact and damaged cells among the groups were statistically significant, likely because of the peripheral areas of damage related to touches between the phacoemulsification tip and the endothelium during irrigation. CONCLUSIONS: The volume of balanced salt solution flow alone did not seem to be a major contributing source of endothelial cell damage and loss, providing further insight into mechanisms of corneal endothelium damage during phacoemulsification.


Assuntos
Extração de Catarata , Facoemulsificação , Animais , Câmara Anterior , Córnea , Endotélio Corneano , Humanos , Coelhos
20.
Artigo em Inglês | MEDLINE | ID: mdl-35505895

RESUMO

Early life experiences are crucial for proper organization of excitatory synapses within the brain, with outsized effects on late-maturing, experience-dependent regions such as the medial prefrontal cortex (mPFC). Previous work in our lab showed that early life sleep disruption (ELSD) from postnatal days 14-21 in the highly social prairie vole results in long lasting impairments in social behavior. Here, we further hypothesized that ELSD alters glutamatergic synapses in mPFC, thereby affecting cognitive flexibility, an mPFC-dependent behavior. ELSD caused impaired cued fear extinction (indicating cognitive inflexibility), increased dendritic spine density, and decreased glutamate immunogold-labeling in vesicular glutamate transporter 1 (vGLUT1)-labeled presynaptic nerve terminals within mPFC. Our results have profound implications for neurodevelopmental disorders in humans such as autism spectrum disorder that also show poor sleep, impaired social behavior, cognitive inflexibility, as well as altered dendritic spine density and glutamate changes in mPFC, and imply that poor sleep may cause these changes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...